Products/Rock Mechanics Products/Acoustic Emissions System

Acoustic Emissions System

Data Acquisition & Digital Signal Processing System

A compact, high-performance 8-channel AE data acquisition and digital signal processing instrument designed for R&D laboratories, universities, and industrial applications.

8 ChannelAE Input
10 MHzSampling Rate
18-bitA/D Resolution
USB-CInterface
Download Brochure
Capable of performing:
Waveform Streaming (5 MSPS)
Continuous AE Monitoring
3D Source Localization
CI / CD Detection
Fracture Characterization
Geomechanical Correlation
Event Visualization & Animation
Publication-Ready Export
FEATURES

Signal Acquisition

  • 8-channel AE instrument with all standard AE measurement features
  • Full AE bandwidth response with sampling up to 10 MHz per channel
  • 18-bit A/D conversion per channel for high-resolution signal capture
  • 1.0 MHz signal bandwidth supporting a wide range of AE applications
  • Continuous waveform streaming at up to 5 MSPS per channel to hard disk
  • Two analog parametric inputs for correlating AE activity with process variables such as load
  • AE hit data and waveforms recorded and accessed through AEwin control software

Connectivity & Power

  • SuperSpeed USB Type-C interface (5 Gbps) ensuring compatibility with any modern PC or laptop
  • Bus-powered directly from the host PC's USB port: no external power supply required
  • Compatible with Windows 10 and newer operating systems

Sensor Compatibility

  • Compatible with PAC Alpha series passive sensors
  • Compatible with PK integral preamp sensors and IL-LP low-power preamplifiers
  • Built-in preamplifier, configurable on/off in software
SPECIFICATIONS
Signal Acquisition
AE Input8 Channel / USB node (up to 3 nodes/system)
Bandwidth Response1.0 kHz to 1.0 MHz
AE DigitizingInternal 18-bit, 10 MSPS A/D per channel
Parametric Inputs2 Channel ±10V, 16-bit, 185 kΩ input impedance
Digital I/OMC USB-1024HLS
PreamplifierBuilt-in, configurable on/off in software
Physical & Power
Case Size3.25″ L (3.85″ to connector ends) × 2.25″ W × 0.63″ H (83 × 57 × 16 mm)
Weight0.15 lbs (65 g)
Power Requirements<100 mA at 5V, supplied by PC's USB port
External InterfaceSuperSpeed USB 3.0, 5 Gbps
Environmental
Operating Temperature32°F – 115°F (0°C – 45°C)
Storage Temperature−4°F – 140°F (−20°C – 60°C)
Operating SystemWindows 10 and above
SOFTWARE

MR-GEO AE

  • Comprehensive desktop analysis application for Acoustic Emission analysis in rock mechanics and geomechanical testing
  • Consolidates data loading, processing, 3D event localization, fracture characterization, and geomechanical correlation into a single, easy-to-use platform
  • Eliminates the need for multiple disconnected tools or custom scripts
  • Runs as a Windows 10/11 desktop application with no external dependencies required

Nine-Step Workflow

  • Read File: Import raw AE data files from industry-standard acquisition systems with automatic channel mapping
  • Filter: Apply coincidence gating and amplitude/frequency filters to isolate meaningful AE events
  • Cluster: Group AE hits using clustering algorithms to reduce raw hit counts to an analysis-ready dataset
  • Localize: Triangulate AE event positions in 3D using TDOA, AIC waveform onset picking, Levenberg–Marquardt optimization, and weighted centroid methods
  • Correlate: Synchronize AE data with geomechanical measurements including deviatoric stress, confining pressure, and axial strain
  • CI/CD Detection: Automatically detect Crack Initiation (CI) and Crack Damage (CD) thresholds with user-adjustable sensitivity
  • Visualize: Generate interactive browser-based 3D plots of event locations within the sample geometry, color-coded by time or sensor count
  • Animate: Play back animated fracture propagation sequences with adjustable opacity for on-plane and off-plane events
  • Export: Output publication-ready charts, fracture plane results, and session data

Core Capabilities

  • Data Loading & Management: Waveform extraction, automatic channel mapping, and compressed session saving for fast reload of large datasets
  • 3D Source Localization: Multiple triangulation methods with configurable wave velocity models and multi-sensor support
  • Geomechanical Correlation: Time-series overlay of AE data with stress, pressure, and strain measurements
  • Interactive 3D Visualization: Real-time Plotly-based 3D visualization with fracture plane overlay and animated event propagation
  • English unit system throughout (psi, inches)
APPLICATIONS

Target Users

  • Rock mechanics testing laboratories
  • Geotechnical and mining engineering teams
  • Academic research groups
  • Energy sector core testing facilities

Use Cases

  • AE monitoring during triaxial, uniaxial, and HPHT core testing
  • Fracture initiation and damage characterization under stress
  • Acoustic emission source localization in 3D
  • Crack Initiation (CI) and Crack Damage (CD) threshold identification
  • Geomechanical correlation of AE events with stress and strain measurements
  • Post-test analysis with animated fracture propagation playback
SAFETY

Electrical Safety

  • Powered exclusively via USB port at 5V, <100 mA: no mains voltage is present within the unit
  • Use only approved USB-C cables and connections to avoid risk of electrical hazard

Operating Environment

  • Ensure the unit is used within the rated temperature range: 32°F – 115°F (0°C – 45°C)
  • Do not expose to moisture, condensation, or corrosive environments

Software Control

  • All channel configurations, preamplifier power, and alarm thresholds must be set via the controlling software before operation
  • Verify all settings prior to each test session
  • Failure to comply with operating guidelines may result in equipment damage or personal injury
Request a Quote

Product Brochure

Fill in your details to receive the product brochure.